products description
The fuse socket and protective cap are both molded from black thermoplastic material, rated UL 94V-0 for flame retardancy, delivering excellent dielectric properties and thermal resistance. The conductive terminal is fabricated from tin-coated copper alloy, which minimizes contact resistance and enhances electrical conductivity. With a pure solder terminal configuration, it is compatible with standard soldering processes. Featuring an IP40 protection rating and PC2 shock-safe construction, this product prevents dust buildup and reduces the risk of accidental electric shock. The maximum supported PCB thickness is 3.5mm, making it suitable for most common circuit boards. It operates reliably across a temperature range of -40°C to 85°C, making it ideal for household appliances and general electronic equipment. This fuse holder complies with IEC, UL, and GB industry standards, holds VDE and UL certifications, and meets RoHS environmental regulations. An optional 50TG snap-on cover can be added for enhanced safety protection.
Engineering Drawing

General Basic Specifications
| Parameter Item | Specification |
| Product Model | H3-50B |
| Product Type | PCB Mounted Shock-Safe Fuse Holder |
| Applicable Fuse Size | 5×20mm |
| Rated Voltage | 250VAC |
| Rated Current | 10A (VDE), 20A (UL) |
| Rated Power Acceptance | 2.5W / 10A @ Ta 23℃ |
| Mounting Method | PCB Board Installation |
| Terminal Type | Solder Terminal |
| Shock-Safe Category | PC2 |
| Protection Degree | IP40 |
| Max PCB Board Thickness | 3.5mm |
| Unit Weight (Socket/Cap) | 3.21g / 2.37g |
Material Configuration
| Component Name | Material Feature |
| Socket & Cap Housing | Thermoplastic, Black, UL 94V-0 |
| Conductive Terminal | Tin-Plated Copper Alloy |
Soldering Technical Parameters
| Test Item | Test Standard & Condition |
| Soldering Methods | Common Soldering Process |
| Solderability | 350℃ / 2sec (IEC 60068-2-20, Test Ta, Method 2) |
| Resistance to Soldering Heat | 350℃ / 10sec (IEC 60068-2-20, Test Tb, Method 2) |
Electrical Insulation Characteristics
| Electrical Parameter | Test Value |
| Contact Resistance | <5mΩ (Test at 20mV) |
| Dielectric Strength (L-N) | >3kV (50Hz, 1min) |
| Dielectric Strength (L/N-PE) | >4kV (50Hz, 1min) |
| Impulse Withstand Voltage (L-N) | >4kV |
| Impulse Withstand Voltage (L/N-PE) | >6kV |
| Insulation Resistance (L-N) | >10MΩ (500VDC, 1min) |
| Insulation Resistance (L/N-PE) | >100MΩ (500VDC, 1min) |
Environmental Application Conditions
| Environmental Item | Parameter Data |
| Operating Temperature Range | -40℃ ~ 85℃ |
| Climatic Category | 40/085/21 (IEC 60068-1) |
| Overvoltage Category | I - III (IEC 60664-1) |
| Pollution Degree | 1 - 3 (IEC 60664-1) |
| Protection Class | Class 1 or 2 (IEC 61140) |
| Storage Temperature | 0℃ ~ 60℃ |
| Max Storage Humidity | 70% R.H. |
Certification & Compliance Standard
| Certification Item | Detailed Information |
| Executive Standards | IEC60127-6, UL4248-1, UL512, GB9364.6 |
| VDE Certificate Number | 134125 |
| UL File Number | E239034 |
| Environmental Compliance | RoHS & China-RoHS Compliant |
| Product Marking | Type, Voltage, Current, Approvals |
Additional Information
| Item | Description |
| Structural Difference | Different mounting hole position compared with H3-50A |
| Derating Curves | Admissible power acceptance decreases with rising ambient temperature |
| Optional Accessory | 50TG Snap-on head cover for H3-50B |
detail pictures