H3-50A Snap-on Cover PCB Mount Fuse Holder
products description
This unit incorporates a solder-only terminal configuration, making it ideal for PCB soldering applications. Rated at IP40 for ingress protection and PC2 for shock-safe operation, the holder effectively keeps out dust and reduces the chance of inadvertent contact with energized components. It supports PCB thicknesses up to 3.5mm, fitting most common board designs. The device performs reliably over a broad operating range from -40°C to 85°C, suitable for diverse and demanding conditions. This fuse holder meets IEC, UL, and GB safety specifications, carries recognized VDE and UL approvals, and is fully compliant with RoHS environmental standards. For enhanced protection, an optional snap-fit cover (model 50TG) can be fitted.
Engineering Drawing

General Basic Specifications
| Parameter Item | Specification |
| Product Model | H3-50A |
| Product Type | PCB Mounted Shock-Safe Fuse Holder |
| Applicable Fuse Size | 5×20mm |
| Rated Voltage | 250VAC |
| Rated Current | 10A (VDE), 20A (UL) |
| Rated Power Acceptance | 2.5W / 10A @ Ta 23℃ |
| Mounting Method | PCB Board Installation |
| Terminal Type | Solder Terminal |
| Shock-Safe Category | PC2 |
| Protection Degree | IP40 |
| Max PCB Board Thickness | 3.5mm |
| Unit Weight (Socket/Cap) | 3.21g / 2.37g |
Material Configuration
| Component Name | Material Feature |
| Socket & Cap Housing | Thermoplastic, Black, UL 94V-0 |
| Conductive Terminal | Tin-Plated Copper Alloy |
Soldering Technical Parameters
| Test Item | Test Standard & Condition |
| Soldering Methods | Common Soldering Process |
| Solderability | 350℃ / 2sec (IEC 60068-2-20, Test Ta, Method 2) |
| Resistance to Soldering Heat | 350℃ / 10sec (IEC 60068-2-20, Test Tb, Method 2) |
Electrical Insulation Characteristics
| Electrical Parameter | Test Value |
| Contact Resistance | <5mΩ (Test at 20mV) |
| Dielectric Strength (L-N) | >3kV (50Hz, 1min) |
| Dielectric Strength (L/N-PE) | >4kV (50Hz, 1min) |
| Impulse Withstand Voltage (L-N) | >4kV |
| Impulse Withstand Voltage (L/N-PE) | >6kV |
| Insulation Resistance (L-N) | >10MΩ (500VDC, 1min) |
| Insulation Resistance (L/N-PE) | >100MΩ (500VDC, 1min) |
Environmental Application Conditions
| Environmental Item | Parameter Data |
| Operating Temperature Range | -40℃ ~ 85℃ |
| Climatic Category | 40/085/21 (IEC 60068-1) |
| Overvoltage Category | I - III (IEC 60664-1) |
| Pollution Degree | 1 - 3 (IEC 60664-1) |
| Protection Class | Class 1 or 2 (IEC 61140) |
| Storage Temperature | 0℃ ~ 60℃ |
| Max Storage Humidity | 70% R.H. |
Certification & Compliance Standard
| Certification Item | Detailed Information |
| Executive Standards | IEC60127-6, UL4248-1, UL512, GB9364.6 |
| VDE Certificate Number | 134125 |
| UL File Number | E239034 |
| Environmental Compliance | RoHS & China-RoHS Compliant |
| Product Marking | Type, Voltage, Current, Approvals |
Additional Information
| Item | Description |
| Derating Curves | Admissible power acceptance decreases with rising ambient temperature |
| Optional Accessory | 50TG Snap-on head cover for H3-50A |
detail pictures