H3-06 PC2 Shock-Safe 6×30mm White Leaded Fuse Holder
products description
The internal conductive terminals adopt pure brass material to maintain ultra-low contact resistance and stable electrical conductivity. With IP40 protection degree, it can effectively prevent dust intrusion and adapt to conventional indoor working environments. There is a clear weight difference between the two models: 3.17g for H3-06A and 5.56g for H3-06B. The applicable wire gauge ranges from 16# to 22# AWG, supporting customized wire length, color and diameter. This product has passed UL certification and complies with international industry standards as well as RoHS environmental protection regulations. It is widely applied in general electronic equipment, industrial control circuits and power protection devices.
Engineering Drawing

General Basic Specifications
| Parameter Item | Specification |
| Product Model | H3-06A / H3-06B |
| Product Type | PC2 Shock-Safe Leaded Fuse Holder |
| Applicable Fuse Size | 6×30mm |
| Rated Voltage | 250VAC / 500VAC |
| Rated Current | 10A (250VAC, UL) / 15A (500VAC) |
| Mounting Method | Wire Connection & Riveting |
| Shock-Safe Category | PC2 |
| Protection Degree | IP40 |
| Applicable Wire Gauge | 16#~22# AWG |
| Unit Weight | 3.17g (H3-06A) / 5.56g (H3-06B) |
Material Configuration
| Component Name | Material Feature |
| Plastic Housing | White Thermoplastic, UL 94V-0 Flame Retardant |
| Conductive Terminal | High Purity Brass |
Electrical Insulation Characteristics
| Electrical Parameter | Test Value |
| Contact Resistance | <5mΩ (Test at 20mV) |
| Dielectric Strength (L-N) | >3kV (50Hz, 1min) |
| Dielectric Strength (L/N-PE) | >4kV (50Hz, 1min) |
| Impulse Withstand Voltage (L-N) | >4kV |
| Impulse Withstand Voltage (L/N-PE) | >6kV |
| Insulation Resistance (L-N) | >10MΩ (500VDC, 1min) |
| Insulation Resistance (L/N-PE) | >100MΩ (500VDC, 1min) |
Environmental Application Conditions
| Environmental Item | Parameter Data |
| Operating Temperature Range | -40℃ ~ 85℃ |
| Climatic Category | 40/085/21 (IEC 60068-1) |
| Overvoltage Category | I - III (IEC 60664-1) |
| Pollution Degree | 1 - 3 (IEC 60664-1) |
| Protection Class | Class 1 or 2 (IEC 61140) |
| Storage Temperature | 0℃ ~ 60℃ |
| Max Storage Humidity | 70% R.H. |
Certification & Compliance Standard
| Certification Item | Detailed Information |
| Executive Standards | IEC60127-6, UL4248-1, UL512, GB9364.6 |
| UL File Number | E239034 |
| Environmental Compliance | RoHS & China-RoHS Compliant |
| Product Marking | Type, Voltage, Current, Approvals |
Accessories & Customization Service
| Part No. & Custom Item | Description |
| EP6300 | Brass Ear Pads |
| 07TH | Special Matching Spring |
| Wire Customization | Wire length, color and diameter customizable |
| MOQ Requirement | Customized products need minimum order quantity |
Additional Information
| Item | Description |
| Structural Feature | White dustproof housing, riveting leaded structure, dual-model design |
| Product Advantage | Dual voltage and current rating, optional two sizes, stable dustproof performance |
| Application Field | General electronic equipment, industrial control devices and power circuits |
detail pictures